Ribbon Sensor and
Gap/Black Mark
Sensor Calibration
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3 Release the button when LED becomes red and blinking.
(Any red will do during the 5 blinks).
It will calibrate the ribbon sensor and gap/black mark
sensor sensitivity.
The LED color will be changed as following order
Amber red (5 blinks) amber (5 blinks) green
(5 blinks) green/amber (5 blinks) red/amber (5
blinks) solid green
Note:
Please select gap or black mark sensor by GAP or BLINE
command prior to calibrate the sensor.
For more information about GAP and BLINE command,
please refer to programming manual.
Gap/Black Mark
Sensor Calibratio,
Label Length
Measurement,
Self Test and enter
Dump Mode
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes amber and
blinking. (Any amber will do during the 5 blinks).
The LED color will be changed as following order.
Amber red (5 blinks) amber (5 blinks) green
(5 blinks) green/amber (5 blinks) red/amber (5
blinks) solid green
It calibrates the sensor and measures the label
length and prints internal settings then enter the
dump mode.
Note:
Please select gap or black mark sensor by GAP or BLINE
command prior to calibrate the sensor.
For more information about GAP and BLINE command,
please refer to programming manual.