Using RFID with Loftware Label Manager
Figure 5.9: A Typical UPC Label with an RFID Field
1. Load (or design) the RFID Smart Label.
a. For this example, add variable text fields that contain values for the Company Prefix, Item
Reference, and Serial Number.
b. For this example, set the length of the Company Prefix value to 6 digits. Set the data sources
for each to Keyboard.
c. Add a barcode field to the label. The barcode, which for this example we will call Barc001,
will contain the GTIN. Set its Data Source to Formula that uses the Combine (&) operation to
concatenate the Company Prefix and the Item Reference.
2. Double click the RFID antenna icon. (Alternatively, select and then right click the RFID antenna
icon. From the popup menu, select Edit Data Source.)
3. From the Data Source dialog, select Block Configuration, and then click the Configure button to
launch the Block Configuration dialog.
4. Select the UHF 96-bit Class 1 tag type.
5. In the EPC block, select EPC from the Data Source column.
Loftware Label Manager Version 10.1.1 User's Guide